Fiberglass Transportation Line Stress Analysis
A 5-inch glass-reinforced epoxy (GRE) transportation line has been installed underground, featuring several above-ground steel pipe connections. Designed to withstand a pressure of 150 bar

A 5-inch glass-reinforced epoxy (GRE) transportation line has been installed underground, featuring several above-ground steel pipe connections. Designed to withstand a pressure of 150 bar

A planned modification to a cokes gas piping involves the installation of a new pipeline to a gas user and the decommissioning of an existing

A stress analysis was conducted on a tubular heat condenser utilizing finite element analysis (FEA). This condenser configuration includes a rotational asymmetric tube bundle secured

In a new industrial process, an existing floating head heat exchanger is being repurposed. The operational conditions involve cyclic loading, which were not originally considered

Introduction Following the replacement of an older tail gas heater, issues with leakage from the top tubesheet flange connection have emerged during production. Despite attempts

This case study details the determination of wall thickness for a Glass Reinforced Epoxy (GRE) tank. Analysis The process of defining the wall thickness was

A gas compressor station, comprising five similar compressor units connected by an inlet and outlet header, is planned for offshore construction in Mexico. Each unit

Dynaflow Research Group (DRG) conducted comprehensive pipe stress analyses for a large oil and gas extraction facility. This facility comprises three onshore flow stations, one

A large-diameter seawater dump caisson, constructed from Glass Reinforced Epoxy (GRE), required a comprehensive strength assessment. This caisson featured five nozzles, with one positioned in

Dynaflow Research Group (DRG) conducted a static analysis of a rectifier or afterwash column, which consisted of a carbon steel shell with a 15 mm

A steel pipeline was under construction for offloading naphtha from ships arriving at a jetty. A surge analysis was conducted to evaluate the pipeline’s capability

DRG was engaged to conduct a comprehensive stress analysis for three sulphur recovery burners, in accordance with ASME VIII Division 1 of the Boiler and

A comprehensive stress and surge analysis was performed for the firewater piping system of an LNG plant located in South America. The system, constructed using

The customer needed to determine the flow split between six cooling towers within a cooling tower arrangement. Analysis The six cooling towers were fed from

This project presented the assessment results of the analysis of the pressure-containing part of an actuator. The focus was on evaluating the actuator’s integrity through

In this study, the details and results of the stress analysis performed for the design of two platforms attached to the reinforcement rings of a

This case study detailed the static and dynamic assessment of a Wintrack Tower. Wintrack Towers represented a new geometrical design for suspension towers for high-tension

Dynaflow Research Group conducted a comprehensive stress analysis on three critical components of a high-pressure heat exchanger: the stationary tubesheet, cone-shaped channel, and shell with

This case study examines the stress analysis conducted on a firewater piping system constructed entirely of Glass Fiber Epoxy (GRE) piping. The system featured a

This case study examines the thermal stress analysis conducted on three critical components of a high-pressure heat exchanger: Stationary tubesheet Cone-shaped channel Shell including cone

This case study examines the static stress analysis conducted on the underground portion of a Seawater Network in a Gas Field development project. The underground

Hydrogen is considered to be a key element in the energy transition. This molecule is the most notable option for the decarbonisation of hard-to-abate sectors

As part of our responsibilities at DRG, we conduct both standard pressure drop calculations and surge/slug analyses for firewater systems. Our involvement spans various stages,

Geothermal energy is a promising renewable energy source, but it comes with its own set of challenges. Two significant issues in geothermal well operations are

Flow-induced vibrations in piping systems are a critical aspect of mechanical engineering, impacting the reliability and integrity of various industrial setups. The Japan Society of

Introduction In the field of engineering design, the precision of pipe flexibility analysis models is critically important for accurately assessing nozzle loads in steel piping

In 2013, a major incident occurred in a Louisiana chemical plant. In a nonroutine operation, plant operators attempted to start a heat exchanger which had

To understand pressure surges in large piping systems, a good place to start is at home. When you finish washing your hands, turning off the

Brief introduction to piping vibrations Vibrations are an oscillatory motion about an equilibrium. The oscillatory movement causes alternating stresses in the system, which, if excessive

The pulsation challenge of a variable speed reciprocating compressorA pulsation analysis according to the API 618 is a good method of preventing excessive vibrations in

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Solving Vibrations In A Two-Phase Process Line Frank Bos Partner Get instant access Free. Recording + slide

ON-DEMAND 🕖 50 MIN 🌏︎ ENGLISH Surge and dynamic stress analysis for an offshore wind farm using BOSfluids Mark Groen Software Lead Engineer

ON-DEMAND 🕖 25 MIN 🌏︎ ESPAÑOL Integración de BOSfluids con Caesar II y otros programas de tensión de tuberías Uri Peker Engineer Get instant

ON-DEMAND 🕖 35 MIN 🌏︎ ENGLISH BOSfluids integration with CAESAR II and other pipe stress programs Ryan Metcalf Manager USA Get instant access

Introduction The flow in the header of a finger-type slug catcher is analyzed using CFD techniques. In order to design a high-performance finger-type slug catcher, it is necessary that the fluid flow in the inlet header manifold is evenly distributed among the different fingers. Analysis A detailed flow analysis by

Combined Pressure Surge and Dynamic Stress Analysis Introduction At BASF Antwerp a steel pipeline was under construction, this pipeline was to be used for the offloading of naphtha from ships arriving at a jetty. The pipeline is 1.6 km long with several pipe bridges. The jetty contains Emergency Release Couplers

Pressure Surge Analysis Introduction An existing power plant of Essent will be extended with a new power plant. The new power plant is based on a Combined Cycle Unit (CCU) which includes the combination of a Gas Turbine with a Steam System. The surface condenser of the new power plant

Combined Pressure Surge and Dynamic Stress Analysis Introduction In the harbor of Antwerp an unloading line was being commissioned for use with cyclohexane. This line features two ship loading arms, located at the end of a jetty. From the loading arms, the unloading line runs towards two storage tanks. Transient

Pressure Surge Analysis Introduction An LNG-plant was planning to construct an additional LNG bunkering line that will be used to fuel ferry ships in Stavanger. Both a main and booster pump are used to achieve the flow through the 600-meter-long pipe line connecting to the ships through a loading arm,

Feasibility Study Introduction A cooling water system consists of a large underground branched GRP piping system connecting to steel branch continuations at each U/G-A/G interface. In the detailed design phase the fitness for purpose of the GRP part of the system will be demonstrated by the GRP supplier by means

Vibrations had been seen in the piping of a reciprocating compressor plant and the operator of the plant was worried that fatigue cracks could occur. Therefore a study was conducted by DRG to determine how the vibration levels could be reduced and whether they were leading to stress levels exceeding

Accumulators are used to reduce pressure pulsations from reciprocating pumps by adding volume to the piping. In the preliminary design stage the size and position of the accumulator needs to be determined before the piping design is completed. The performance of the system including the pump and connected piping is

Commercially available pulsation analysis software uses either a transient (time domain) or harmonic (frequency domain) solver. A time domain solver is more accurate for determining the pulsation amplitude, but solving in the frequency domain can be orders of magnitude faster. Which solver should you use and why is there a

When purchasing or delivering a reciprocating pump an API674 pulsation study might be required. The API 674 describes two different design approaches in Annex C (2010 edition). This post describes the most important differences between the design approaches and the pro’s and con’s between the two approaches. Regardless of the

Third-party review of fiberglass EPC project in Oman Dubai, 2 March 2017 DRG is probably best known for their large involvement in all facets of fiberglass design and engineering. It ranges from component design such as fittings and elbows for suppliers, qualification of the fiberglass products, engineering calculations as well

Infield inspections Oman – enhancing processes & performance July 2016 The link between assessment and performance As engineers, we are happiest when we are out in the field making our customers’ projects run more smoothly. DRG’s niche is the link between assessment and performance, and two projects in Oman recently

DYNAFLOW RESEARCH GROUP (“DRG”) Enters into Reseller Agreement with Quality Professional Software (“QPS”) RIJSWIJK, The Netherlands – January 24, 2024 (Dynaflow Research Group BV) –

Dynaflow Research Group and Seawind Ocean Technology announce collaboration focusing on technical readiness of floating offshore wind applications in the Mediterranean Sea. This landmark partnership