
Stress Analysis For Platforms On A Vacuum Tower
Introduction This case study recounts the stress analysis conducted for the design of two structural platforms attached to reinforcement rings on a vacuum tower. These

Introduction This case study recounts the stress analysis conducted for the design of two structural platforms attached to reinforcement rings on a vacuum tower. These

Introduction This study detailed the mechanical calculations for four internal components designed as gas inlet distributors within a pressure vessel. These internals were welded to

Introduction In the past, visible vibrations were observed in the piping connected to hydrogen compressors. These vibrations were particularly noticeable in the small-bore pipes branching

Introduction In this case study, a burst test was conducted to demonstrate the strength of a DN1200 Glass Fiber Reinforced Plastic (GRP) pipe. The objective

Introduction In the context of a compression station project, DRG conducted a comprehensive static stress analysis encompassing the plant inlet, slug catcher, and filter areas.

Introduction In this case study, we delve into a static stress analysis concerning a distillate water header within a remineralization unit of a desalination plant.

Introduction In the analysis conducted for the gas-inlet top box of a heat exchanger, which forms a part of the Torrefaction Tower, emphasis was placed

Introduction In the context of a greenfield project centered on the construction of a power plant, fiberglass-reinforced plastic (GRP) pipes with diameters of approximately 2.5

Since its beginnings, in 1989, Dynaflow Research Group (DRG) has been involved in shaping the landscape of fiberglass engineering through research, design engineering, and consultancy.

Introduction In this case, slender steel conical towers are designated to support high-tension wires, subjecting them to various horizontal and vertical load components. The load

Introduction In the examination of our client’s initiative to assess and enhance the primary cooling water system within an established power plant, various configurations, and

Date: April 2nd, 2024 We are delighted to announce the celebration of Dynaflow Research Group’s 35th anniversary, marking a significant milestone in our journey of

Introduction The seawater system was classified as a class A system per the Service Limit State (SLS) standards. Constructed from reinforced fiberglass piping, it comprised

Introduction In this case study, the focal point was addressing the high vibration levels observed in the process piping extending from a heat exchanger to

Introduction In this case study, we addressed a notable vibration issue observed in the main 16” line at a chemical plant, which was suspected to

Introduction This case involved fulfilling a client’s request to perform a surge analysis and static and dynamic stress analysis about the cooling water lines and

Introduction In this case study, the focus was on conducting a stress analysis of the GRE piping system utilized to link the pumps to the

Introduction As a result of a failure in a fiberglass header in the undercroft of a chilled water system, the decision was made to replace

Introduction In the process of extending an existing power plant, the addition of a new power plant was deemed necessary. This new facility was designed

Introduction In this case study, we delved into the stress analysis findings regarding the revised flue gas overhead line in Singapore connecting a third-stage separator

Introduction In the current project, a static stress analysis was conducted to assess the performance of GRE headers connected to filter vessels. The purpose was

Hydrogen is considered to be a key element in the energy transition. This molecule is the most notable option for the decarbonisation of hard-to-abate sectors

As part of our responsibilities at DRG, we conduct both standard pressure drop calculations and surge/slug analyses for firewater systems. Our involvement spans various stages,

Geothermal energy is a promising renewable energy source, but it comes with its own set of challenges. Two significant issues in geothermal well operations are

Flow-induced vibrations in piping systems are a critical aspect of mechanical engineering, impacting the reliability and integrity of various industrial setups. The Japan Society of

Introduction In the field of engineering design, the precision of pipe flexibility analysis models is critically important for accurately assessing nozzle loads in steel piping

In 2013, a major incident occurred in a Louisiana chemical plant. In a nonroutine operation, plant operators attempted to start a heat exchanger which had

To understand pressure surges in large piping systems, a good place to start is at home. When you finish washing your hands, turning off the

Brief introduction to piping vibrations Vibrations are an oscillatory motion about an equilibrium. The oscillatory movement causes alternating stresses in the system, which, if excessive

The pulsation challenge of a variable speed reciprocating compressorA pulsation analysis according to the API 618 is a good method of preventing excessive vibrations in

ON-DEMAND 🕖 30 MIN 🌏︎ ENGLISH Understanding and Mitigating AIV and FIV in Modern Plant Design David Tickner Senior Engineer Get instant access

ON-DEMAND 🕖 30 MIN 🌏︎ ENGLISH How To Predict Stresses From Slug Flows Daniëlle de Jong Senior Engineer Get instant access Free recording

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Building models using the import PCF file feature & model verification In BOSfluids Thijs Krijger Project Engineer

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Solving Vibrations In A Two-Phase Process Line Frank Bos Partner Get instant access Free. Recording + slide

ON-DEMAND 🕖 50 MIN 🌏︎ ENGLISH Surge and dynamic stress analysis for an offshore wind farm using BOSfluids Mark Groen Software Lead Engineer

ON-DEMAND 🕖 25 MIN 🌏︎ ESPAÑOL Integración de BOSfluids con Caesar II y otros programas de tensión de tuberías Uri Peker Engineer Get instant

ON-DEMAND 🕖 35 MIN 🌏︎ ENGLISH BOSfluids integration with CAESAR II and other pipe stress programs Ryan Metcalf Manager USA Get instant access

Within Europoort Rotterdam, a tankpit of 37m diameter and 21m height was intended to be repurposed for storing a blend of Naphtha and Reformate. Reformate, a product of Naphtha, shares similar chemical properties, with both fluids being miscible (they mix well together). Dynaflow Research Group performed a CFD analysis on

For a coil-wound liquified natural gas (LNG) heat exchanger, an existing 66” and new 72” bolted flange joint have been analysed and reviewed for mechanical loading and multiple thermal load cases in accordance to the 2013 edition of ASME VIII Div.1 and Div.2 by Dynaflow Research Group (DRG) using ANSYS

Dynaflow Research Group (DRG) has performed a stress and surge analysis using BOSfluids at Rotterdam Maasvlakte on an extension to their firewater system to accommodate the loading of LNG onto ships and barges at the jetty area. The extension of the firewater system consisted of an underground glass-reinforced epoxy (GRE)

An existing fiberglass firewater piping system was expanded to enhance its capacity, necessitating validation for the newly added components. The client, engaged in the RDCG Rotterdam capacity growth project, specializes in producing renewable fuels through the chemical conversion of vegetable and animal oils. The firewater system at this facility is

Our client was looking to repurpose a liquid transport and storage system for a different fuel. The new fuel blend has a larger viscosity and density. Heat tracing is applied to the pipe line to reduce the liquid viscosity during transport. The new fuel is pumped into a storage tank,

Our client reported multiple cracks at weld locations on a separation tank. These cracks are suspected to be caused by dynamic flow effects from the mixed inflow of acid gas and liquid. To address this issue, the client requested a Computational Fluid Dynamics (CFD) analysis to quantify the forces exerted

A client approached Dynaflow with concerns about potential dynamic loads on their piping system during the activation of a Pressure Safety Valve (PSV) protecting a degasser. During PSV opening, both gas and liquid (methane and water) are discharged together, creating complex flow conditions that could lead to transient forces and

The EVO-42 compressor package, featuring a screw compressor, oil separator, motor, dampener, and associated piping, was subject to a comprehensive evaluation by Dynaflow Research Group. This study aimed to assess its mechanical and acoustic performance under operating conditions, following the guidelines set out in API 619 and ASME VIII Div.

A client operates a reciprocating compressor at their terminal facilities, which is integral to their gas processing operations. During routine operations, excessive vibrations were observed within the system, raising concerns regarding equipment reliability, safety, and compliance with relevant industry standards. The compressor system in question features a 6-cylinder design with

The Tesoro Salt Lake City Refinery initiated a project to reduce the sulfur content in its products, necessitating modifications to the piping system on the discharge side of compressors K-701A/B. These changes prompted concerns about excessive pulsations and vibration-induced stresses, particularly as no previous pulsation study had been conducted. The
Heat exchangers are essential in industrial applications for transferring heat between fluids. However, they are susceptible to multiple mechanical failures, being one of them flow-induced vibrations (FIV). This case study examines a specific incident where a heat exchanger experienced multiple failures at the welded connections of tube bundles to the

In the chemical processing industry, equipment integrity under extreme conditions is paramount for safety and efficiency. This case study examines the thermal and mechanical analysis of a 2” equal tee subjected to high-temperature fluidized catalyst streams. The project’s objective was to assess the tee’s integrity where a 690°C catalyst stream

The offshore oil and gas industry encounters distinctive challenges in managing high-pressure piping systems, where the repercussions of failure can be dire. Therefore, ensuring the structural integrity of these piping systems is paramount. This case study examines a critical investigation conducted during the Detailed Design Phase of an Offshore Topside

A petrochemical facility has been experiencing recurring failures in its fiberglass piping Cooling Water (CW) network. With seven failures reported up to 2014 and a recent failure in November 2023, the integrity of the system has come under scrutiny. As the fiberglass piping approaches its 20-year design lifetime, a comprehensive

A fiberglass gas pipeline is being implemented to supply gas from a compressor station to a delivery point. As the pipeline approaches completion, ensuring its operational safety and integrity is paramount. This case study examines the surge analysis conducted on the buried portion of the pipeline to identify potential vulnerabilities

An ammonia plant in Australia has experienced recurring failures in its cooling water systems since its commissioning in the mid-2000s. The plant utilizes two primary cooling systems: a Sea Cooling Water (SCW) system and a Fresh Cooling Water (FCW) system. The SCW system, with a high capacity, consists of multiple

This case study examines the structural integrity of an industrial pressure vessel subjected to cyclic thermal and pressure loading. In processes where such vessels experience significant temperature and pressure fluctuations, ensuring the longevity and safety of these critical components is paramount. The primary objective of this study is to assess

This case study examines the structural integrity of header boxes in an industrial air cooler heat exchanger subjected to cyclic thermal loading and static pressure. In processes where heat exchangers experience significant temperature fluctuations, ensuring the longevity and safety of critical components is paramount. The primary objective of this study

Floating Production Storage and Offloading (FPSO) units play a crucial role in offshore oil and gas production. A critical component of these systems is the compressor skid, which compresses natural gas for processing or export. This case study focuses on the pulsation and vibration analysis of a three-stage reciprocating compressor

This case study examines a reciprocating compressor system operated by a leading energy company, used for compressing natural gas. The system consists of three identical compressor units, each with two stages (suction and discharge pulsation suppression devices and connected piping), supplying gas to a common header. This system had been

This case study examines the cooling water and foam systems located in two jetties (Jetty A and Jetty B) of a major industrial facility. These systems, critical for fire protection, have experienced significant issues related to water hammer effects and structural integrity. The primary objectives of this study are to

DYNAFLOW RESEARCH GROUP (“DRG”) Enters into Reseller Agreement with Quality Professional Software (“QPS”) RIJSWIJK, The Netherlands – January 24, 2024 (Dynaflow Research Group BV) –

Dynaflow Research Group and Seawind Ocean Technology announce collaboration focusing on technical readiness of floating offshore wind applications in the Mediterranean Sea. This landmark partnership