Pulsations Paper
Benefit of computational simulation of a pulsation dampener compared to an analytical method Accumulators are used to reduce pressure pulsations from reciprocating pumps by adding

Benefit of computational simulation of a pulsation dampener compared to an analytical method Accumulators are used to reduce pressure pulsations from reciprocating pumps by adding

ON-DEMAND 🕖 50 MIN 🌏︎ ENGLISH Acoustically Induced Fatigue in Gas Filled Piping Systems Using BOSfluids Remco Boere Senior Software Engineer Get instant access

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Simulation Strategies and Practical Application for Vapour Cavity Formation Dr. Ir. Erik Jan Lingen Software Director Get

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Fundamentals, Failure Mechanisms, and Engineering Consequences of Vapor Cavity Formation Dr. Ir. Erik Jan Lingen Software Director

ON-DEMAND 🕖 45 MIN 🌏︎ ENGLISH Bridging the Gap: From NFPA 15 Steady-State Design to Transient Surge Analysis in Tank Terminals Uri Peker

ON-DEMAND 🕖 45 MIN 🌏︎ ENGLISH Support Stiffness Effects on Mechanical Natural Frequencies in Reciprocating Compressor Piping Systems Thijs Krijger Project Engineer Get

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Beyond hydraulics: a practical guide to fire water analyses with BOSfluids Dr. Ir. Erik Jan Lingen Software

AIV Fundamentals At what pipe diameter and wall thickness should one be concerned about AIV? What is the relevant D/T ratio? This depends on the

ON-DEMAND 🕖 3 SESSIONS x 45 MIN 🌏︎ ENGLISH Complete Pulsation Analysis Using BOSpulse Tim Gebraad Software Lead Engineer Marienne Faro Software Sales Engineer

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Getting the Timing Right: Why Time Step Size Is Critical In Surge Analysis Dr. Ir. Erik Jan

ON-DEMAND 🕖 30 MIN 🌏︎ ENGLISH Protecting Tank Terminal Assets Through Surge and FFS Analyses Thijs Krijger Project Engineer Katrine van Overhagen Engineer

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Choosing the right GRE piping standard: a comparison of ISO 14692 and ASME NM.2 Edwin Schimmel Project Engineer

ON-DEMAND 🕖 50 MIN 🌏︎ ENGLISH How Stepless Capacity Control Shapes Flow and Pulsations Thijs Krijger Project Engineer Get instant access Free. Recording

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Water Hammer Analysis & Mitigation in Pipeline Systems with BOSfluids Dr. Ir. Erik Jan Lingen Software Director

ON-DEMAND 🕖 60 MIN 🌏︎ ENGLISH Water Hammer Analysis & Mitigation in Pipeline Systems with BOSfluids Dr. Ir. Erik Jan Lingen Software Director

ON-DEMAND 🕖 35 MIN 🌏︎ ENGLISH Understanding, Modelling, and Managing Thermal Bowing using CAESAR II David Tickner Senior Engineer Get instant access Free.

What are the key challenges in applying CFD to simulate and optimize multiphase processes in complex industrial systems? The main challenge here is the ability

Do CAESAR II formulas for thermal bowing and output results match with FEA? Short Answer: There can be significant differences between the results of CAESAR II and FEA.Explanation:The

ON-DEMAND 🕖 35 MIN 🌏︎ ENGLISH Using CFD for optimizing multiphase process engineering Bart van der Zalm Senior Engineer Get instant access Free.

DRG CONFERENCE – 35TH ANNIVERSARY 🌏︎ ENGLISH Innovations that Change the Engineering Industry Get instant access Free. Recording + slide deck available Event Description

ON-DEMAND 🕖 35 MIN 🌏︎ ENGLISH Fatigue Assessment According to ASME B&PV VIII Div.2 Lukas Bajarunas Senior Software Engineer Get instant access Free

ON-DEMAND 🕖 45 MIN 🌏︎ ENGLISH Fiberglass Piping Stress Envelope According to ISO 14692 using CAESAR II Edwin Schimmel Project Engineer Get instant

This case study focuses on the vibration assessment of a pentane line, specifically evaluating vibration stresses and the risk of fatigue issues at the nozzle/shell interfaces. Vibration measurement data provided by the client was analyzed. Initially, it was hypothesized that the vibration problem stemmed from a mechanical resonance phenomenon, implying

A gas metering skid is being designed for use in a flow station. DRG was commissioned by a client to conduct a comprehensive noise and vibration study of the metering skid to assess its vulnerability to fatigue failure. The potential for fatigue failure arises if the mechanical resonance modes of

Large amplitude vibrations in a process line have resulted in damage to several pipe supports. DRG was engaged to identify the root cause of these vibrations, assess potential fatigue issues, and recommend remedial actions for the client. Analysis DRG performed a comprehensive visual inspection to determine the resonance modes being

Surge analysis in LNG bunkering systems is essential to ensure safe and efficient operations, particularly when fueling ferry ships. This analysis involves evaluating several worst-case scenarios to understand surge phenomena in a 600-meter long LNG bunkering line. The system utilizes a main pump and a booster pump to achieve flow,

A branch connection linking to a high-pressure steam attemperator has experienced a failure, similar to a previous incident. Observations on-site indicate periodic movement of the connecting header housing equipment J-3103, suggesting a fatigue failure. The objective of this analysis is to propose a permanent solution to prevent future cracks in

This project involves a feasibility study for designing a flue gas duct in a carbon capture and storage plant. The scope includes conceptualizing two large-diameter, thin-walled ducts that connect a heat exchanger to two boiler units. One of these ducts spans over an existing plant section, necessitating careful consideration of

At an oil refinery plant in Saudi Arabia, a fiberglass-reinforced plastic (FRP) pipe fire water system has been installed, predominantly buried underground. Since its installation, the system has experienced several failures. DRG was tasked with conducting a comprehensive pipe stress analysis to assess the system’s integrity. This analysis focused on

In a new industrial process, an existing floating head heat exchanger is being repurposed. The operational conditions involve cyclic loading, which were not originally considered during its design phase. To evaluate the impact of these cyclic loads on the heat exchanger, Dynaflow Research Group conducted a comprehensive fatigue analysis. Analysis

A gas compressor station, comprising five similar compressor units connected by an inlet and outlet header, is planned for offshore construction in Mexico. Each unit features three compressor stages that elevate the gas pressure from ambient levels to 95 bar. This substantial pressure increase is accompanied by a significant temperature

Dynaflow Research Group (DRG) conducted comprehensive pipe stress analyses for a large oil and gas extraction facility. This facility comprises three onshore flow stations, one offshore flow station, and a gas export compressor station. Crude oil and gas are transported from the wells to the flow stations, where the crude

A steel pipeline was under construction for offloading naphtha from ships arriving at a jetty. A surge analysis was conducted to evaluate the pipeline’s capability under various transient upset scenarios. Following this, a dynamic stress and flexibility study was performed based on the calculated pressure surges. Analysis A transient one-dimensional

A comprehensive stress and surge analysis was performed for the firewater piping system of an LNG plant located in South America. The system, constructed using Glassfiber Reinforced Epoxy (GRE) pipes, underwent a dynamic response analysis to account for the largest and most critical unbalanced forces. Surge Analysis The existing firewater

This case study examines the detailed fatigue stress analysis conducted on a heat exchanger used to heat Polyol before it entered a refinery reactor. The complex 8-pass, U-tube configuration with a flanged stationary tube sheet required thorough investigation to ensure operational integrity and longevity. Analysis Methodology Engineers identified and analyzed

In this case study, a number of critical sections in an already installed fire water system were selected for review. At the time of the analysis, earlier on-site interventions had already been made, motivated by pipe failures. The analysis aimed to determine if additional interventions were necessary. Analysis Based on

This case study describes the stress analysis performed on a firewater piping system located in the Middle East. The system was constructed using Glassfier Reinforced Epoxy (GRE) pipes. Most of the piping was buried underground and included several connections to above-ground steel piping, fire hydrants, and similar equipment. Analysis The

Introduction At a Flow Station in Nigeria, vibration issues were observed in the suction and discharge headers, as well as the pump recirculation line. To address these concerns and identify potential underlying issues, DRG conducted a comprehensive pulsation analysis combined with a mechanical response assessment. Analysis A stress model was

Introduction In this case study, we explored the pulsation and vibration phenomena at a gas compression station equipped with four centrifugal compressors. These compressors generate flow pulsations due to the action of the impellors, which can excite the system’s acoustic and mechanical natural frequencies. To understand and evaluate the system’s

Introduction During the start-up and normal operation phases of a Gasoil Hydrofiner system, significant vibrations were observed in its piping. These vibrations, described as “large amplitude,” were particularly concerning. The unit’s piping was divided across four separate pipelines. Analysis Upon examining the system under various process conditions, it was determined

Pressure surges ocurr in piping systems whenever there are sudden changes in flow resistance from steady operation. Surges can cause significant damage, also at locations far removed from where they are initiated. For large or complex piping systems, this can make their impact challenging to predict without specialist analysis. Dynaflow

Introduction In this case study, we encountered undesirable vibrations in the downstream line of an angle control valve within a wash oil line. Initially, the upstream wash oil boasted a pressure of 150 bar and a temperature of 400°C. However, downstream of the valve, there was a significant pressure drop

Introduction A surge analysis and static stress analysis were necessitated for an FRP ballast water system following a prior incident to prevent its recurrence. The ballast system’s function was to redistribute water among compartments to balance oil storage. Analysis Surge Analysis One of the main objectives of the surge analysis