Spring-Supported Tie-In, 114 mm Wellhead Movement
A new tie-in connects a wellhead to an 8″ header on a North Sea platform through a 6″ line. Elsewhere on the platform the piping is designated medium stiff, for which the operator’s specification permits simplified screening based on flow velocities.
The tie-in line could not be designated medium stiff, because springs are fitted to accommodate wellhead movement of 114 mm vertically and 25 mm in the north, south, east and west directions. A detailed vibration analysis was therefore required, and the scope stated that any modifications needed for conformance should be kept to a minimum and discussed with the client before calculation.
Three flow-induced failure mechanisms were analysed: acoustic fatigue, mechanical resonance due to turbulence, and vortex shedding from tees. The restrictive nature of the choke valve leads to turbulence downstream, the magnitude of which depends on the pressure drop across the valve. Upstream of the valve the maximum design pressure is 46.0 MPa and the hot design temperature 121 °C; downstream they are 18.0 MPa and 98 °C. The line material is ASTM A790 S31803.
Acoustic Modelling, Vortex Shedding and Fatigue Assessment
Acoustic power downstream of the choke valve was calculated by the formula of Carucci and Mueller and compared against the allowable acoustic power of Eisinger.
Acoustic resonance frequencies were determined with a one-dimensional transient fluid model built in BOSfluids, complemented by hand calculations. The model ran from the choke valve to the end of the supplied piping model, including part of the 8″ header, with both header ends treated as open boundaries. A step change in pressure applied at the choke valve location excited frequencies of 11.3 and 22.6 Hz, which correspond with those calculated from the open/open relationship.
The modelled header was then extended, first by 20 m upstream and then by 20 m either side. The 11.3 Hz frequency was still excited in both cases, and the second extension also excited a mode at approximately 15 Hz due to the system length. Frequencies dependent on the header length were discounted, as the header and the other wellheads could not feasibly be modelled and system lengths change in operation with flow conditions and valve closures.
Both operating cases have a pressure decrease of approximately 1 bar across the choke valve. Achieving this requires some throttling, so the valve cannot necessarily be treated as a fully open boundary. The open/closed frequencies of 5.6 and 17.0 Hz were therefore considered alongside the open/open values, and each frequency was analysed over a band of ±10%.
The amplitude of an excited fundamental mode was taken as 2% of the pressure difference across the valve, the upper end of the 1 to 2% range given by Blevins. Blevins does not quantify the reduction at higher modes, so a decrease of 1.5 dB per higher resonance mode was taken, consistent with the value Rogers proposes for vortex shedding. The resulting unbalanced forces were based on the 2P fourth year case, which has the largest pressure drop across the valve. They were applied between elbow pairs, with those on short sections between elbows taken as negligible. The CAESAR II piping model was then run with each of the three resonance modes that could be excited in the frequency range up to 30 Hz, a limit determined from the open area of the choke valve.
Vortex shedding was assessed by the method of Rogers. Strouhal-based shedding frequencies were plotted against flow velocity in the 6″ line on an interference diagram, together with the quarter-wave and three-quarter-wave acoustic natural frequencies of the dead-end branches. Of the six dead-end branches, the four short branches showed no overlap; the two longer liquid and gas testing branches did. Their unbalanced pressures were calculated by the method of Rogers, based in turn on that of Jungowski et al., assuming at least 1 mm rounding on the inside of each branch intersection. Decay along the 6″ line was taken from the attenuation relationship in the NORSOK standard.
With the unbalanced forces from the acoustic resonance modes and from vortex shedding applied to the CAESAR II model, the resulting dynamic stresses, treated as amplitudes, were assessed as per ASME B31.3 Section K304.8. The assessment used the fatigue curve of Table 3.F.3 of ASME B&PV VIII-2. As the title of that curve was judged not to cover duplex stainless steel explicitly, its use was justified from literature sources.
Stress intensification factors at the weldolet connections to the small-bore branches were calculated by finite element analysis, as ASME B31.3 advises using more applicable values than the code values where they are available. Stress intensification factors in an ASME B31.3 assessment are referenced to a butt weld, while the fatigue curve is based on a polished bar. The stresses from the CAESAR II model were therefore multiplied by two, a rounded estimate of the stress concentration at a butt weld. In model terms, the permissible cyclic stress amplitude of 93 MPa for more than 1×10^11 cycles corresponds to 46 MPa.
The 6″ line was assessed in three parts and the branches in four, so that dynamic stresses were not conservatively added from different parts of the system. Dynamic stress amplitudes above 5 MPa were carried into the fatigue assessment. Only one frequency is excited for a given acoustic mode, so the largest peak across that mode’s frequency bands was taken. Likewise, one peak was taken per shedding frequency band. Within each part these peaks were added, as several modes may be excited at once and the harmonically related acoustic modes are in phase.

Acoustic Power 109 dB and Fatigue Amplitudes Under 93 MPa
The acoustic power downstream of the valve was 105 dB for the 2P first year case and 109 dB for the 2P fourth year case, against an allowable acoustic power of 173 dB; both cases conformed with the acoustic fatigue check.
The acoustic resonance modes gave minimal excitation of mechanical resonance modes in the 6″ line and the branches, with a maximum dynamic stress amplitude of 2 MPa in the branches. The unbalanced forces due to vortex shedding were more critical than those due to excitation of the acoustic resonance modes. The largest arose from the liquid testing branch in the 2P first year case: an unbalanced pressure of 28,200 Pa and an unbalanced force of 950 N over a shedding frequency range of 23.5 to 30.5 Hz. Across the two testing branches, the shedding frequency bands lay between 23.5 and 95 Hz.
No acoustic resonance mode produced a dynamic stress amplitude above 5 MPa, so every peak carried into the fatigue assessment came from vortex shedding: up to 20 MPa in the 6″ line and 30 MPa in the branches. The largest combined amplitude was 20 MPa in Part 3 of the 6″ line and 40 MPa in Part 3 of the branches, the latter from three peaks of 19, 8 and 13 MPa. Applying the factor of two gives 40 MPa and 80 MPa for comparison against the permissible amplitude of 93 MPa. All parts of the 6″ line and the branches remained under the endurance limit, with a desired 3.15×10^10 cycles (10 years at 100 Hz) against 1×10^11 permissible cycles.
On the basis of this fatigue assessment against ASME B&PV VIII-2, the tie-in, including the small-bore branches, conforms with ASME B31.3 for flow-induced vibration. No modifications are required to the system as shown in the received isometrics.

Spring Supports, Branch Length, Choke Boundaries and Model Division
Where springs accommodate wellhead movement, the piping cannot be designated medium stiff. The velocity screening that the operator’s specification permits for medium stiff lines therefore does not apply, and a detailed vibration analysis is needed.
In this tie-in, branch length decided whether vortex shedding could occur. For the short dead-end branches the lowest acoustic natural frequency lay far above the possible shedding modes, so no overlap arose. The acoustic natural frequencies of the longer testing branches overlapped the shedding modes, and their vortex shedding produced every stress peak in the fatigue assessment. The stresses from the acoustic modes driven by the choke valve stayed below 5 MPa.
A throttled choke valve cannot necessarily be treated as a fully open acoustic boundary, which is why the open/closed frequencies were assessed alongside the open/open set.
Dividing the model into parts prevented dynamic stresses from different parts of the system being added conservatively, while the peaks within each part were still added together.

Frequently Asked Questions
When does a wellhead tie-in need a detailed flow-induced vibration assessment?
Where springs are fitted to accommodate wellhead movement, the piping cannot be designated medium stiff. The simplified velocity screening that the operator’s specification permits for medium stiff lines then does not apply. On this tie-in the springs accommodate 114 mm of vertical and 25 mm of horizontal wellhead movement, so a detailed vibration analysis was required.
How were the acoustic resonance frequencies downstream of the choke valve found?
A one-dimensional transient fluid model in BOSfluids, complemented by hand calculations, was excited with a step change in pressure at the choke valve. With both header ends treated as open boundaries, it showed 11.3 and 22.6 Hz, matching the open/open relationship. The 11.3 Hz frequency was still excited when the modelled header was extended by 20 m upstream, and then by 20 m either side.
Can a throttled choke valve be treated as an open acoustic boundary?
Not necessarily. Both operating cases have a pressure decrease of approximately 1 bar across the valve, which requires some throttling. The open/closed frequencies of 5.6 and 17.0 Hz were therefore considered alongside the open/open frequencies of 11.3 and 22.6 Hz, each analysed over a ±10% band.
What pressure amplitude was assumed for turbulence-excited acoustic modes?
The fundamental mode was taken at 2% of the pressure difference across the valve, the upper end of the 1 to 2% range given by Blevins. Blevins does not quantify the reduction at higher modes, so a decrease of 1.5 dB per higher mode was applied. This value is consistent with the one Rogers proposes for vortex shedding.
Why are CAESAR II stresses doubled for an ASME B31.3 K304.8 fatigue check?
ASME B31.3 Section K304.8 directs the fatigue assessment to the ASME B&PV VIII-2 curve, which is based on a polished bar. Stress intensification factors in an ASME B31.3 assessment are referenced to a butt weld. Multiplying the CAESAR II stresses by two, a rounded estimate of the stress concentration at a butt weld, means the permissible amplitude of 93 MPa for more than 1×10^11 cycles corresponds to 46 MPa in the model.
Which dead-end branches caused vortex shedding?
Only the two longer liquid and gas testing branches did. Their quarter-wave and three-quarter-wave acoustic natural frequencies overlapped the shedding modes. For the four short branches, the lowest acoustic natural frequency lay far above the shedding modes. The largest unbalanced force, 950 N from an unbalanced pressure of 28,200 Pa, arose from the liquid testing branch in the 2P first year case over 23.5 to 30.5 Hz.
Did the choke valve pass the acoustic fatigue check?
Yes. Acoustic power downstream of the valve was 105 dB in the 2P first year case and 109 dB in the 2P fourth year case, against an allowable acoustic power of 173 dB.
Do the small-bore branches on the tie-in need modification?
No. After the factor of two, the largest combined amplitude in the branches was 80 MPa against a permissible 93 MPa, and every part remained under the endurance limit. The tie-in, including the small-bore branches, conforms with ASME B31.3 for flow-induced vibration, and no modifications are required to the system as shown in the received isometrics.