Inter-Stage Overpressure and Surge Loads in Three Valve Upset Scenarios
The inter-compressor lines on a gas compression station carry gas between compression stages and cross a bridge between two platforms. A preceding process study addressed concerns in the pressure regulation system: whether the inter-stage pressure could be kept below the maximum allowable working pressure (MAWP). That study described three upset scenarios, A1 to A3, each including a valve that closes in 2 s.
In scenario A1, the pressure control valve PCV-2902 opens from fully closed to fully open in 5 s and exposes the rest of the system to a pressure of 88 Barg. Valve XZV-2905 trips at 35 Barg and closes in 12 s. Overpressure protection valve XZV-25001 trips at 33.5 Barg and closes in 2 s to protect the low-pressure (LP) line. In scenarios A2 and A3, an air failure causes the high-pressure (HP) inlet shutdown valve XZV-26001 to close in 2 s. As analysed, A2 includes the overpressure protection trip at 40 Barg and the compressor trip at 35 Barg; A3 takes no credit for either.
In A1, the pressure rises through the system as PCV-2902 opens. The 12 s closure of XZV-2905 then produces only a small pressure wave downstream and a surge wave travelling upstream. In A2 and A3, the fast closure of XZV-26001 abruptly stops the flow and causes a pressure surge. A pressure difference between adjacent bends produces an unbalanced force on the pipe between them. The surge assessment addressed two questions: whether these unbalanced forces could overstress the piping or its supports, and whether the pressure peaks could exceed the piping MAWP. The design pressure is 99.3 Barg for the HP piping and 45 Barg for the LP outlet piping.
A BOSfluids Transient Flow Model Paired With a CAESAR II Piping Model
The work combined two analyses. A transient flow analysis determined the magnitude of the pressure surges. A mechanical response study then applied the resulting unbalanced forces to the piping model to find the stresses, restraint loads and displacements.
The flow and dynamic stress analyses needed the entire line in one model. The relevant piping from two existing static stress models, one of the brownfield platform and one of the greenfield platform, was therefore combined in CAESAR II. To avoid duplicate node numbers, the node numbers of the brownfield model were incremented by 10,000. The transient flow model was built in BOSfluids, a package for one-dimensional fluid transients in piping systems. Surge stresses were assessed against ASME B31.3, and flange loads against ASME Boiler and Pressure Vessel Code Section III Division 1, paragraph NC-3658.3.

Compressible Flow, Valve Modelling, Model Checks and Dynamic Load Cases
The high pressure difference through the system made the gas flow subject to compressibility effects, and the flow through the valves upstream of the HP inlet was choked. BOSfluids, as is normal for a fluid transient package, is based on the propagation of small pressure disturbances, so the effect of compressibility under large pressure differences was checked.
The check rested on the Joukowsky equation, in which the pressure rise is linearly proportional to the product of density and velocity change. As density decreases, the velocity change increases. The product therefore remains constant after valve closure, and an inaccuracy in density does not affect the resulting pressure rise. To confirm this and to check that the worst case was covered, A1 and A2 were each run with natural gas densities of 21.4 and 29.5 kg/m³, corresponding to reference pressures of 29 and 40 Barg.
The valve closure curves were not available, so typical closure curves for ball valves were used. The discharge coefficients were based on the valve Cv values in the process study. To represent the choked flow, they were reduced where necessary to match the process study’s transient pressure profiles.
The model was validated at steady state against Case 4A of the heat and material balance in the process study, comparing pressures and mass flows at three locations.
For A1, the surge results were compared with the UniSim results from the process study, directly upstream of valve XZV-26001. The UniSim model was set up to find the maximum pressure that could occur in the LP piping and used a fixed flow boundary at the HP inlet. The BOSfluids model was set up to find the largest pressure differences between adjacent bends, which produce the unbalanced loads. It used either a fixed pressure (case 1) or a variable pressure (case 2) boundary at the HP inlet. The pressure increase is similar in both, but it rises to approximately 85 Barg in UniSim and only to approximately 50 Barg in BOSfluids case 1. Case 2 gave slightly smaller pressure differences in the system and lower unbalanced loads, so the remaining assessment focused on case 1.
From the flow model, the time-varying unbalanced force between each pair of bends was extracted and applied in the middle of the length between the two elbows. Force histories with an amplitude above 5 kN were imported into CAESAR II and solved with its time-history solver. The 5 kN limit was based on the support allowables and the static restraint loads from the existing static analysis.
The unbalanced forces in A2 are significantly smaller than in A1, and A3 shares the XZV-26001 closure event of A2. The closures of the overpressure protection valves produced no pressure surge, because there was no flow from the LP side when they closed. Two dynamic load cases were analysed with the unbalanced forces from A1 and A2. L1 combines weight, pressure and dynamic loads as an occasional stress check for burst or collapse. L2 adds operating temperature to determine the restraint loads, which combine the static operating and dynamic contributions. The recorded clearance gaps at multiple supports were included.
Stress, Flange, Pressure, Displacement and Restraint Load Results
The dynamic stresses remained within the ASME B31.3 occasional allowable for all three scenarios. The occasional allowable is 1.33 times the hot allowable. That gives 183.9 MPa for A333 Gr. 6, from a hot allowable of 138.3 MPa, and 275.04 MPa for A790 S31803, from a hot allowable of 206.8 MPa. The pressure peaks remained below the HP and LP piping MAWP, and in A1 the pressure in the LP piping did not exceed the 45 Barg MAWP. All flanges conformed to the NC-3658.3 allowable for dynamic loading, which is twice the static allowable, for the worst case of A1 and A2.
Support friction may prevent displaced piping from returning to its original position, so repeated upsets may build up displacement. To avoid displacements exceeding 10 mm, axial stops were recommended at three existing support locations: node 2310 on the HP line and nodes 4410 and 4810 on the LP line. The static models were rechecked with these supports, and the changes did not adversely affect stress or restraint and nozzle loads. Close to the bridge, the dynamic displacements exceed 30 mm. The movement of the bridge between the platforms prohibits additional supports there.
The dynamic restraint loads exceeded the support allowables at a number of supports. The static restraint loads from the existing static analysis also exceeded these allowables at some locations.

Axial Stop Relocation and Its Effect on Static Restraint and Nozzle Loads
At the recommended locations, shear lugs would have to be welded to the pipe. Strictly speaking, this welding would require pressure tests and post-weld heat treatment to be repeated. A later request asked whether the axial stops could instead be placed on existing dummy legs nearby (option A). In those positions the stops are no longer ideally placed with respect to the thermal expansion of the pipe. Their static restraint loads, based on the maximum design temperature, increased:
| Original stop | Static load (N) | Relocated stop | Static load (N) |
|---|---|---|---|
| Node 2310 | 13,498 | Node 2357 | 115,313 |
| Node 4410 | 18,452 | Node 4305 | 38,434 |
| Node 4810 | 6,304 | Node 4705 | 36,037 |
Static pipe stresses remained within ASME B31.3. The nozzle loads on the vessel at the LP outlet increased fourfold; they were not explicitly assessed.
A possible interchange of spools in the LP piping of the metering skid (option B) would move the stops at nodes 4410 and 4810 to nodes 4455 and 4855. Compared with option A, the restraint loads did not change substantially, and the nozzle loads on the same vessel were reduced by a factor of two.
If option A is adopted, the static stress analyst should check that its restraint and nozzle loads are within their allowables. The alternative recommended is a shear lug at each original location.
Surge Support Placement and Restraint Allowables
An axial stop added to limit surge displacement also restrains the thermal expansion of the pipe. When the stops were relocated, the dynamic contribution to the restraint loads stayed nearly constant, because the unbalanced loads are unaltered by the change in support location. The static restraint loads, by contrast, rose at all three stops. A stop location chosen from the dynamic model therefore needs confirming in the static model, as was done here for both the original and the relocated stops.
Because the existing static analysis also showed restraint loads above the support allowables at some locations, the allowable values may be underestimated there. The recommendation was a review of those values by the static stress analyst, together with a check of the support structure against the dynamic restraint loads.

Frequently Asked Questions
Does gas density uncertainty affect the surge pressure rise in a transient flow model?
Not for the pressure rise caused by valve closure. In the Joukowsky equation, the pressure rise is linearly proportional to the product of density and velocity change. As density decreases the velocity change increases, so the product remains constant after valve closure. Here, scenarios A1 and A2 were each run with natural gas densities of 21.4 and 29.5 kg/m³, at reference pressures of 29 and 40 Barg, to confirm this and to check that the worst case was covered.
How high were the surge pressures in the initial design?
The time-varying unbalanced force between each pair of bends was taken from the BOSfluids model and applied in the middle of the length between the two elbows. Force histories with an amplitude above 5 kN were imported into CAESAR II and solved with its time-history solver. The 5 kN limit was based on the support allowables and the static restraint loads from the existing static analysis.
What allowable was used for surge stresses under ASME B31.3?
The surge stresses were checked against the occasional allowable, taken as 1.33 times the hot allowable. That is 183.9 MPa for A333 Gr. 6 and 275.04 MPa for A790 S31803. The dynamic stresses remained within it for all three upset scenarios.
How were the dynamic flange loads assessed?
Flange loads were assessed against ASME Boiler and Pressure Vessel Code Section III Division 1, paragraph NC-3658.3, where the allowable for dynamic loading is twice the static allowable. All flanges conformed for the worst case of scenarios A1 and A2.
Why did the BOSfluids and UniSim surge pressures differ?
Each model was set up for a different purpose. UniSim looked for the maximum pressure in the LP piping and used a fixed flow boundary at the HP inlet. BOSfluids looked for the largest pressure differences between adjacent bends and used a fixed or variable pressure boundary at the HP inlet. Directly upstream of valve XZV-26001 in scenario A1, the pressure increase is similar, but it rises to approximately 85 Barg in UniSim and only to approximately 50 Barg in BOSfluids case 1.
Why did static restraint loads rise when the axial stops were moved to existing dummy legs?
In the new positions the stops were no longer ideally placed with respect to the thermal expansion of the pipe. The static load at the stop moved from node 2310 to node 2357 rose from 13,498 N to 115,313 N, and the other two relocated stops also increased. The dynamic contribution stayed nearly constant, because the unbalanced loads are unaltered by the change in support location.
What does it indicate when restraint loads exceed the support allowables in both the static and dynamic results?
In this case the existing static analysis also showed restraint loads above the support allowables at some locations, so the allowable values may be underestimated there. The recommendation was a review of those values, together with a check of the support structure against the dynamic restraint loads.