Slug and Hammer Analysis of HIPPS Valve Closure on a 16-inch/12-inch Gas Riser Line

ON THIS PAGE

Slug Impact on a Closing HIPPS Valve

A 16-inch steel gas riser lands on a platform, and a 12-inch line branches off the riser into the platform. A HIPPS valve on the 12-inch branch protects the downstream platform from pressures exceeding 150 Barg. The 16-inch riser is exposed to slug flow, and the impact of a liquid slug on the closing HIPPS valve generates a pressure rise upstream of the valve.

An incident case was specified for the analysis. A liquid slug of 12 cubic metres, 114 metres long in the 16-inch riser and composed mainly of water, travels at 9.5 metres per second and impacts the HIPPS valve while the valve closes in 2.1 seconds. The analysis determined the maximum line pressure and the unbalanced load time histories on the riser. The riser is carbon steel (API 5L), with a design pressure of 350 Barg and a design temperature of 50 °C.

Simplified Hammer Analysis and Critical Closure Time

Two analyses were made: a simplified slug analysis by hand calculation and a detailed transient simulation in BOSfluids. The simplified analysis determined the critical closure time of the valve. A quasi one-dimensional approach was assumed, with all interfaces perpendicular to the pipe centreline. When the valve closes while the slug is passing through it, a compression wave travels upstream through the slug, reflects at the upstream gas/liquid interface and returns to the valve. The critical closure time is twice the slug length divided by the speed of sound in the slug, and a valve with a longer closure time is classed as slow closing.

For the 12 cubic metre slug, with a slug length of over 100 metres, the critical closure time was 0.18 seconds. Both closure times considered, 1.8 and 2.1 seconds, are longer than this, so the valve is classed as slow closing. For a slow-closing valve the maximum hammer pressure can be estimated by hand with a modified Joukowsky formula, which relates it to the slug density, the slug length and the maximum fluid deceleration during closure. For a fixed closure time, a linear velocity time history gives a constant deceleration and the lowest hammer pressure. A parabolic velocity time history has twice the maximum deceleration of the linear history, and so twice the estimated hammer pressure.

Because the critical closure time depends on the slug volume, sensitivity calculations were made for a range of slug volumes, and also for the two closure times. The lowest hammer pressure, 8.1 Barg, corresponded to the 2.1-second closure with a linear velocity time history and the smallest slug volume considered, 8 cubic metres. The highest, 26.9 Barg, corresponded to the 1.8-second closure with a parabolic velocity time history and the largest slug volume. The formula does not account for pressure wave reflections.

BOSfluids Transient Model of the Slug and HIPPS Valve

The detailed stage used BOSfluids to model the slug inside the riser together with the closing valve. The model included wave reflections at the upstream end and at the valve, and its output gave a speed of sound in the slug of 1420 metres per second. The simulation started from a steady state in which the slug flowed towards the HIPPS valve at 9.5 metres per second and the pressure upstream of the valve had reached 135 Barg, the pressure at which the valve was assumed to start closing. Across the slug the pressure difference was approximately 10 Barg, part of which resulted from the gravity-related pressure gradient in the riser.

OSfluids pipe model of a carbon steel gas riser line coloured by steady-state pressure at the start of HIPPS valve closure.
BOSfluids model of the riser line to the HIPPS valve, coloured by steady-state pressure at the start of valve closure.

The 12-inch on/off ball valve was modelled with both a linear and a parabolic stroke time history. The valve has an almost parabolic stroke-capacity characteristic. Given this characteristic, and with the open area modelled as proportional to stroke, a linear stroke time history corresponds to a linear velocity time history, and a parabolic stroke time history to a parabolic velocity time history. The influence of the gas upstream of the slug was neglected, because the major fraction of the pressure wave travelling through the slug is reflected at the slug end.

Two scenarios were examined. In Case 1, the valve starts closing when the front of the slug has just passed the valve, so no gas is enclosed between the slug and the closing valve. In Case 2, the valve starts closing while the slug is still approaching, so a volume of gas lies between the slug front and the closing valve, and gas initially passes through the valve. Case 2 was simulated for a range of enclosed gas volumes, with a linear stroke and a 2.1-second closure.

Peak Pressures and Unbalanced Loads at HIPPS Closure

In Case 1, with a 12 cubic metre slug, a 2.1-second closure and a linear stroke, the maximum pressure was 164 Barg, upstream of the HIPPS valve. This corresponds to a maximum pressure increment of approximately 30 Barg above the 135 Barg steady-state pressure. With a parabolic stroke and the same slug and closure time, the maximum pressure was lower. Maximum pressures for both stroke time histories were also determined for a range of slug volumes.

Maximum line pressure against slug volume for linear and parabolic valve stroke, with the slug passing the valve during closure (Case 1).

With a 12 cubic metre slug and 1 cubic metre of gas enclosed between the slug and the valve at the start of closure, Case 2 gave a maximum pressure of around 190 Barg upstream of the HIPPS valve. From the same steady-state pressure, this corresponds to a short-duration pressure increment of 55 Barg, 25 Barg more than the Case 1 increment. The maximum amplitude of the unbalanced loads was about twice that in Case 1 with a linear stroke. The maximum pressure varied with the enclosed gas volume and showed a local maximum at around 1 cubic metre.

For the most relevant load cases, the unbalanced load time histories were determined on a per-node basis for use in a structural dynamic simulation of the riser.

CaseValve strokeEnclosed gas at start of closureMaximum pressure upstream of HIPPSIncrement above 135 Barg
1LinearNone164 BargApproximately 30 Barg
1ParabolicNoneLower than linearNot stated
2Linear1 cubic metreAround 190 Barg55 Barg

Design Findings for HIPPS Closure Against Slug Flow

The maximum line pressure in this configuration occurred when the valve started closing before the slug reached it and around 1 cubic metre of gas was enclosed between the slug and the valve. That condition was identified by simulating a range of enclosed gas volumes.

Graph of maximum pressure against gas volume enclosed ahead of the slug, with a local maximum near 1 cubic metre.
Maximum pressure against volume of gas enclosed between slug and HIPPS valve at the start of closure, linear stroke and 2.1-second closure (Case 2).

The simplified hand calculation classed the valve as slow closing and gave a first estimate of the hammer pressure, but its formula neglects pressure wave reflections. Including the travelling waves in the simulation completely changed the picture generated by the manual calculations, and the line packing they generate may result in pressures somewhat higher than the manual calculations predict.

In the simplified analysis the parabolic velocity time history gave the higher hammer pressure, while in the simulation of the on/off ball valve the largest pressures occurred with a linear stroke, which corresponds to a linear velocity time history. The study strongly recommended including the unbalanced load time histories in a structural analysis and support design of the line.

Frequently Asked Questions

How is the critical closure time of a valve against a liquid slug calculated?

It is twice the slug length divided by the speed of sound in the slug. During closure, a compression wave travels upstream through the slug, reflects at the upstream gas/liquid interface and returns to the valve. A valve that takes longer than the critical closure time to close is classed as slow closing. For the 12 cubic metre slug, with a slug length of over 100 metres, the critical closure time was 0.18 seconds, so closure times of 1.8 and 2.1 seconds place the HIPPS valve in the slow-closing category.

A modified Joukowsky formula relates the maximum hammer pressure to the slug density, the slug length and the maximum fluid deceleration during closure. For a fixed closure time, a linear velocity time history gives a constant deceleration and the lowest hammer pressure. A parabolic velocity time history gives twice the maximum deceleration of the linear history, and so twice the estimated hammer pressure. In this study the hand estimates ranged from 8.1 to 26.9 Barg. The formula does not account for pressure wave reflections.

The BOSfluids model included wave reflections at the upstream end and at the valve, which the Joukowsky estimate neglects. Including the travelling waves completely changed the picture generated by the manual calculations. The line packing generated by the travelling waves may result in pressures somewhat higher than the manual calculations predict. The two methods also ranked the closure histories differently: the hand calculation gave the higher estimate with a parabolic velocity time history, while the simulation gave the largest pressures with a linear stroke, which corresponds to a linear velocity time history for this valve.

In this analysis, 1 cubic metre of gas enclosed between a 12 cubic metre slug and the valve at the start of closure gave a maximum pressure of around 190 Barg upstream of the HIPPS valve. That is a short-duration increment of 55 Barg above the 135 Barg steady state, 25 Barg more than the increment with no enclosed gas. The maximum amplitude of the unbalanced loads was about twice as high. The maximum pressure showed a local maximum at around 1 cubic metre of enclosed gas.

In the BOSfluids simulation of the 12-inch on/off ball valve, the linear stroke gave the higher pressure. With a 12 cubic metre slug and a 2.1-second closure, the linear stroke produced a maximum of 164 Barg upstream of the valve, and the parabolic stroke a lower maximum. In the simplified hand calculation, the parabolic velocity time history gave the higher estimate.

For the most relevant load cases, the unbalanced load time histories were determined on a per-node basis for use in a structural dynamic simulation of the riser. The study strongly recommended including them in a structural analysis and support design of the line.