Flow-Induced Vibration Assessment of a Gas Metering Manifold Before Single-Line Operation

ON THIS PAGE

Why Single-Line Metering Raises Gas Velocity and ρV² in the 10-Inch Pipe

The natural gas flow metering station on a platform had three parallel metering lines, two active and one spare. The operator decided to replace the orifice-type flow meter in the most eastern line with an ultrasonic flow meter. Once the new meter was installed, the complete gas flow would be directed through it, and one metering line would be operated instead of two in parallel.

An ultrasonic flow meter does not require a constriction of the pipe cross-section, so vortex shedding at the meter is less obvious than at an orifice-type meter. The modified operating mode would raise gas velocities in the 10-inch metering pipe above 20 m/s.

At these velocities, and with the applicable gas density, the gas momentum flux would reach values above 2,000 N. At this level, a relatively small flow variation, for example 5 percent, would result in load variations of the order of 200 N, and pipe load variations of this order may result in pipe vibration.

The resulting maximum stagnation head, ρV² = 44,000 kg/(m·s²), would not comply with the line sizing criteria of the operator’s general specification. To comply with that specification, an assessment was required to determine whether vibration problems would arise in the system.

Excitation Mechanisms in the 10-Inch Metering Pipe

For sustained vibration to occur, an excitation mechanism has to interact with the dynamic properties of the piping system. The assessment first made an inventory of the excitation mechanisms and then compared them with these properties. Five flow cases were assessed: the two most extreme cases, 1 and 5, and three intermediate cases. Three excitation mechanisms were considered.

The first is vortex shedding. Even without the orifice constriction, vortices are generated at bends, valves and other discontinuities at the velocities of single-line operation, and the resulting pressure fluctuations produce shaking forces in the piping. The shed vorticity has a preferred frequency, expressed in terms of a Strouhal number, which for internal flow past discontinuities varies between 0.2 and 0.3.

The excitation frequency depends on the flow rate. The frequencies of particular interest are 13 to 21 Hz for a Strouhal number of 0.2 and 19 to 31 Hz for a Strouhal number of 0.3, because they lie close to the first two acoustic natural frequencies. The most important excitation frequencies therefore lie between 13 and 31 Hz. The magnitude of the shaking forces is proportional to the variation in momentum, and so to the velocity squared. Although the station will be operated at several flow rates, the largest flow rate is in general the most critical, since larger velocities result in higher shaking forces.

The second mechanism is acoustic resonance in the form of standing waves. Pressure oscillations generated in the metering pipe may cause acoustic resonance if the excitation frequency coincides with one of the acoustic natural frequencies of the system. For the 10-inch section between the upstream and downstream 12-inch headers, the first acoustic natural frequency varies closely around 14 Hz and the second harmonic around 28 Hz. These values assume that the 50 percent cross-sectional change between the 10-inch and 12-inch pipe acts as an open reflection interface for acoustic waves.

The third mechanism is random acoustic excitation from turbulence. According to the literature, for example ASME PVP 41, broadband turbulent excitation in internal flow has a diameter-related frequency cutoff of 10 Hz for the 10-inch pipe. This mechanism was therefore not of large interest here.

CAESAR II Modal Analysis and Acoustic Lock-In

Two types of mode shape were considered. Cross-sectional “breathing” modes, in which the pipe cross-section deforms, were not considered further, because following Blevins the first two have natural frequencies of 1,000 Hz and higher. Beam-type modes, in which the pipe deflects like a beam, were calculated with a dynamic model of the piping, including its supports, built in CAESAR II from the supplied isometrics and piping specification. The first 40 natural frequencies of the system were extracted.

CAESAR II model of the gas metering manifold, including the three parallel metering lines.

The first eight mode shapes are rigid-body movements of the manifold. From mode 9 onwards, deformation of the manifold and the pipe plays a role. The modes at 14.196 Hz and 28.512 Hz are related to lateral movement of the piping and can be excited relatively easily by the vortex shedding and acoustic excitation described above.

The first two acoustic natural frequencies, around 14 Hz and 28 Hz, lie within the vortex shedding band of 13 to 31 Hz, so lock-in may easily occur. In lock-in, the pressure and velocity fluctuations from the acoustic standing waves trigger vortex separation, which in turn amplifies the pressure fluctuations. This applies in particular to flow cases 3 and 4, whose excitation frequencies of 13.7 Hz and 26.3 Hz lie closest to the acoustic natural frequencies.

Lock-In Risk Near 14 and 28 Hz and the Recommended Guides and Stops

The comparison of excitation mechanisms with the dynamic properties of the piping indicated that a possible vibration risk exists. The risk is largest around 14 Hz and around 28 Hz, where the vortex shedding frequencies coincide with the first two acoustic natural frequencies of the gas. Lock-in at these frequencies would give the largest pressure fluctuations in the flow. The structural natural frequencies closest to these excitation frequencies respond most easily to the flow dynamics and present the largest risk: lock-in can excite the lateral modes at 14.196 Hz and 28.512 Hz and cause large displacements in the structure.

Two options were considered to limit the vibration risk. Increasing the pipe diameter would reduce the velocity and break the interaction between acoustics and vortex shedding, but this was not a realistic option from a cost and production perspective. The recommended option is stiff lateral guiding at the supports and stop supports in the manifold, which will shift the natural frequencies and thereby eliminate the risk of mechanical resonance.

Frequency Checks for Single-Line Gas Metering After a Meter Change

Replacing the orifice-type meter with an ultrasonic meter removes the constriction at the meter, but at the velocities of single-line operation vortices are still shed at bends, valves and other discontinuities. In this case those vortices give excitation frequencies close to the acoustic natural frequencies of the 10-inch section between the 12-inch headers, and the lateral piping modes at 14.196 Hz and 28.512 Hz lie close to both.

The momentum flux above 2,000 N and the non-compliance of ρV² with the line sizing criteria were the reasons for the assessment; the vibration risk was identified by comparing the flow-induced excitation frequencies with the acoustic and structural natural frequencies. For the magnitude of shaking forces, the largest flow rate is in general the most critical. The excitation frequencies closest to the acoustic natural frequencies came from flow cases 3 and 4, which are intermediate cases within the five assessed.

Frequently Asked Questions

Does replacing an orifice meter with an ultrasonic flow meter remove vortex shedding in gas metering piping?

An ultrasonic flow meter needs no constriction of the pipe cross-section, so vortex shedding at the meter is less obvious than at an orifice-type meter. At the velocities of single-line operation, above 20 m/s in the 10-inch metering pipe, vortices are still generated at bends, valves and other discontinuities. The resulting pressure fluctuations produce shaking forces in the piping.

For internal flow past discontinuities, the Strouhal number varies between 0.2 and 0.3. In this assessment, the excitation frequencies of particular interest were 13 to 21 Hz at a Strouhal number of 0.2 and 19 to 31 Hz at 0.3, because they lie close to the first two acoustic natural frequencies of the 10-inch section.

In lock-in, the pressure and velocity fluctuations from acoustic standing waves trigger vortex separation, which in turn amplifies the pressure fluctuations. Here the first two acoustic natural frequencies, around 14 Hz and 28 Hz, lie within the vortex shedding band of 13 to 31 Hz, so lock-in may easily occur. Flow cases 3 and 4, at 13.7 Hz and 26.3 Hz, lie closest to the acoustic natural frequencies.

According to the literature, for example ASME PVP 41, broadband turbulent excitation in internal flow has a diameter-related frequency cutoff of 10 Hz for a 10-inch pipe. This mechanism was therefore not of large interest in this assessment.

In this case the maximum stagnation head of 44,000 kg/(m·s²) would not comply with the line sizing criteria of the operator’s general specification. With the momentum flux above 2,000 N, a flow variation of 5 percent would result in load variations of the order of 200 N. To comply with the specification, an assessment was required to determine whether vibration problems would arise.

Stiff lateral guiding at the supports and stop supports in the manifold will shift the natural frequencies of the piping and thereby eliminate the risk of mechanical resonance. This was the recommended option. Increasing the pipe diameter would reduce the velocity and break the interaction between acoustics and vortex shedding, but it was not a realistic option from a cost and production perspective.