Pipe Stress, Flange and Vessel Nozzle Load Assessment of 6-Inch and Smaller Piping
A Floating Production, Storage and Offloading (FPSO) platform that will operate off the west coast of India carries two process systems built from 6-inch and smaller piping: a condensate dewatering system and a fuel gas system. A flexibility analysis of both systems, including flange and nozzle assessment, was performed against ASME B31.3 for the piping and the additional project requirements. The analyses were mostly based on the project stress analysis design basis.
Parts of the piping needed modification for ASME B31.3 code compliance, and a modified support arrangement was developed so that no vessel nozzles remain overstressed. The work was to assess both systems and recommend the modifications needed for all system components to comply with the applicable code and specification.
CAESAR II Model Scope and Wind and Earthquake Load Basis
Both systems were modelled and assessed in CAESAR II, following their isometric drawings. Additional isometric drawings were added to the original scope because the piping shown on them was found to need modification for ASME B31.3 code compliance.
Earthquake loads were not considered, in accordance with the project stress analysis design basis and in line with the nature of a floating production platform. The effects of earthquake-generated tsunami-type wave loads were also not taken into account. A maximum wind speed of 30.4 m/s was applied, as stated in the design basis.
Sixteen Load Cases and the Equivalent Pressure Method
The assessment used sixteen load cases: one hydrotest case, three operating cases with thermal loads T1, T2 and T3, one sustained case for weight and pressure, eight occasional cases and three expansion cases. The occasional cases apply two wind loads, WIN1 and WIN2, each in the positive and negative direction. Four combine wind with the sustained loads and four combine it with the operating loads at T3. The expansion cases are the differences between the T1 and T2 operating cases, and between each of those two operating cases and the sustained case.
Each load case was assigned to the components it checks. The hydrotest, sustained and expansion cases and the four sustained-plus-wind occasional cases were assessed against ASME B31.3. The operating cases and the four operating-plus-wind occasional cases were used for the support, flange and nozzle checks, and the sustained case was also used for the flange and nozzle checks. The operating allowable for flanges was checked with operating conditions only.
Flanges were assessed with the equivalent pressure method. The external axial force F and bending moment M on a flange are converted into pressure terms and added to the design pressure Pdes to give the equivalent pressure Peq, which is compared with the rated flange pressure in the ASME B16.5 rating table:
Peq = 4F / (πG²) + 16M / (πG³) + Pdes
where G is the gasket diameter. Peq and Pdes are in N/mm², F in N, M in N·mm and G in mm. The axial force is included only when it acts in tension and is taken as zero in compression.
Restraint Changes, Flange Relocation and Allowables
The modifications proposed to keep the piping stresses within the ASME B31.3 allowables change the support arrangement, specifically restraint type and location, and include a few minor reroutes. All modifications are shown on marked-up isometrics.

For gasket diameters below 1,000 mm, the bending moment term generally has a larger influence on the equivalent pressure than the axial force term. Where possible, flange connections were therefore relocated to reduce the bending moments on them and so the equivalent pressure at the flange face.
The design basis requires the equivalent pressure to be lower than the hydrotest pressure. For both systems the hydrotest pressure is higher than the ASME B16.5 rated pressure. The flanges were assessed against the ASME B16.5 rated pressure, a conservative approach, and against the hydrotest pressure only where that rating was exceeded. On the condensate dewatering system, some 900# flanges exceeded the ASME B16.5 rated pressure and were checked against the hydrotest pressure.
The individual allowables for nozzles N1 and N2 on HS-6150A and B are forces of 12,000 N (FL), 12,000 N (FA) and 9,000 N (FC) and moments of 4,680 N·m (MC), 5,400 N·m (MT) and 4,680 N·m (ML). The vendor also gives a maximum combined load onto the vessel of 10,000 N in X, −10,000 N in Y and 8,000 N in Z.
Nozzle, Flange and Pipe Stress Results After Modification
The nozzle load and pipe stress results are for the modified system. With the modified support arrangement, no overstressed nozzles remain. On the fuel gas system, nozzles N1 and N4 of VN-6160, and N1 and N2 of FS-6140A and B and of HS-6150A and B, were checked for operating conditions against the allowable nozzle loads in the design basis. All nozzle loads are within their allowable values.
On HS-6150A and B the individual load components are well within their allowable range, and the vendor’s maximum combined load is the more restrictive limit.

Where necessary, the isometrics were modified to keep all piping stresses within the allowable limits of ASME B31.3. The piping, flanges and vessel nozzles were analysed for the specified design and operating conditions. When the recommended modifications are implemented, all system components will comply with the applicable code and specification.
Lessons for FPSO Piping, Flange and Nozzle Load Checks
Code compliance can depend on piping beyond the original isometric scope. On this project, additional isometrics were added because the piping on them needed modification for ASME B31.3 compliance.
For flanges with gasket diameters below 1,000 mm, the bending moment term generally has a larger influence on the equivalent pressure than the axial force term. Relocating flange connections where possible to reduce the bending moment therefore addresses the larger of the two terms.
The flange assessment also used the allowables in two steps. The design basis set the hydrotest pressure as the limit. That pressure was higher than the ASME B16.5 rated pressure, so checking against the rated pressure first was conservative. The hydrotest pressure was used only where a flange exceeded the rating, as some 900# flanges on the condensate dewatering system did.
On the HS-6150A and B nozzles, the vendor’s maximum combined load was more restrictive than the individual load allowables, so a vendor-supplied combined limit needs checking alongside the individual allowables.

Frequently Asked Questions
What load cases were used in the FPSO piping flexibility analysis?
Sixteen in total: one hydrotest case, three operating cases with thermal loads T1, T2 and T3, one sustained case for weight and pressure, eight occasional cases and three expansion cases. The occasional cases apply wind loads WIN1 and WIN2 in the positive and negative direction: four combined with the sustained loads and four with the operating loads at T3. The hydrotest, sustained, expansion and sustained-plus-wind cases were assessed against ASME B31.3. The operating and operating-plus-wind cases were used for the support, flange and nozzle checks, and the sustained case was also used for the flange and nozzle checks.
Were earthquake and wind loads included?
Wind was included and earthquake was not. In accordance with the project stress analysis design basis and in line with the nature of a floating production platform, earthquake loads were not considered, and earthquake-generated tsunami-type wave loads were not taken into account. A maximum wind speed of 30.4 m/s was applied, as stated in the design basis.
How is the flange equivalent pressure calculated?
The external axial force F and bending moment M are converted into pressure terms and added to the design pressure: Peq = 4F / (πG²) + 16M / (πG³) + Pdes. Here G is the gasket diameter, Peq and Pdes are in N/mm², F is in N, M is in N·mm and G is in mm. The axial force is included only in tension and is taken as zero in compression. Peq is then compared with the rated flange pressure in the ASME B16.5 rating table.
Why relocate a flange connection to reduce its equivalent pressure?
For gasket diameters below 1,000 mm, the bending moment term generally has a larger influence on the equivalent pressure than the axial force term. Moving a flange connection to a location with a lower bending moment reduces the larger of the two terms. On this project, flange connections were relocated where possible for that reason.
Which flange allowable applies when the hydrotest pressure is higher than the ASME B16.5 rated pressure?
On this project the design basis required the equivalent pressure to stay below the hydrotest pressure. For both systems the hydrotest pressure was higher than the ASME B16.5 rated pressure. The flanges were assessed against the rated pressure, a conservative approach, and against the hydrotest pressure only where that rating was exceeded. That applied to some 900# flanges on the condensate dewatering system.
Can a vendor’s combined nozzle load limit be more restrictive than the individual nozzle allowables?
It was on this project. For nozzles N1 and N2 on HS-6150A and B, the individual load components were well within their allowables of 12,000 N (FL), 12,000 N (FA), 9,000 N (FC), 4,680 N·m (MC), 5,400 N·m (MT) and 4,680 N·m (ML). The vendor’s maximum combined load onto the vessel, 10,000 N in X, −10,000 N in Y and 8,000 N in Z, was the more restrictive limit.
What modifications bring the FPSO piping into compliance?
The recommended modifications change the support arrangement, specifically restraint type and location, and include a few minor reroutes, all shown on marked-up isometrics. With the modified support arrangement no overstressed nozzles remain. When the recommended modifications are implemented, all system components will comply with the applicable code and specification.