Nozzle Load Feasibility Analysis for Floating LNG Compressor Piping

ON THIS PAGE

Wind, Barge Motion and API 617 Limits on Large-Bore Compressor Piping

On a floating LNG (FLNG) platform, natural gas is compressed in a module installed near the centre of the barge. Four large-bore lines connect to that compressor: a 52-inch low-pressure suction line, a 36-inch medium-pressure suction line, a 30-inch high-pressure suction line and a 28-inch discharge line.

In addition to thermal and pressure design loads, the piping on an FLNG module is exposed to two external load sources. The platform must remain safely in operation under extreme environmental conditions, so the design has to accommodate storm winds with a velocity of 85 m/s acting along the barge centreline. The barge also rocks in response to wave action, and at the compressor location this motion produces accelerations of 0.3 g vertical, 0.2 g transverse and 0.1 g longitudinal. Wind and wave loads may deflect and bend the lines and generate additional compressor nozzle loads.

For piping of this type, the pipe material stress is seldom the limiting design criterion; the allowable compressor nozzle loads to API 617 generally set the limit. The API 617 nozzle load limits are more restrictive for larger-bore piping. The study illustrates the effect with a simplified calculation. If the bending moment is assumed to make the main contribution to the API 617 criterion for the 1200 NB nozzle on the 52-inch suction line, the bending stress in the connected pipe at the allowable limit is 1.9 MPa. The allowable stress for the pipe material, A312 Type 316 stainless steel, is 137.9 MPa. A limit of 1.9 MPa is not feasible in practice, which shows that API 617 was not specifically developed for large-bore compressor piping.

Conflicting Support Requirements and Acceptance Criteria

A support arrangement designed for wind and barge motion loads is in principle in conflict with one designed for thermal expansion. For thermal expansion the target is maximum flexibility; for external loads a restraining support arrangement is preferred. The design task was to find a layout and support arrangement that accommodates both without overloading the compressor nozzles.

Because the API 617 allowables are very restrictive for large-diameter nozzles, a factor of four was applied to the basic allowable figures. The target was that the loads on every nozzle stay within four times the API 617 allowable under all load conditions, and that pipe material stresses stay within the ASME B31.3 allowables.

Wall Thickness Sizing and CAESAR II Load Case Modelling

The work proceeded in two stages. First, the required pipe wall thickness was established from pressure containment at design pressure for A312 Type 316 material. For the final arrangement, the wall thicknesses used were 11.13 mm for the 52-inch line, 7.92 mm for the 36-inch line and 6.35 mm for the 30-inch line, all at a design pressure of 20 barg, and 11.91 mm for the 28-inch discharge line at a design pressure of 40 barg.

Second, each layout was modelled in CAESAR II, with wall thicknesses based on the first-stage calculation. A support arrangement was developed for each layout to minimise the compressor nozzle loads. All layouts were exposed to the same thermal and environmental conditions. The nozzle load results for the second and third arrangements cover 14 load cases:

  • weight with design pressure and temperature, hot and cold;
  • weight with working pressure and temperature (normal operation);
  • working conditions with 85 m/s wind;
  • working conditions with each of four ship movements, with and without wind;
  • weight with design or working pressure at ambient temperature.

The approach was iterative: analyse a layout and use the lessons from its results to develop the next.

Compressor Orientation, Piping Loops and Axial Stops

A number of layouts were analysed in stages, and the last three are described here. The first of these placed the compressor centreline on the barge centreline. The piping was kept as short as possible, on the basis of experience in previous assessment studies, to limit the length exposed to wind and inertia loads. Most of this piping ran in the ship’s axial direction, which is also the wind direction, and the layout had limited flexibility. The study expected the resulting pipe bending to produce unacceptably high nozzle loads, and the results confirmed this.

The second arrangement reoriented the compressor centreline perpendicular to the barge centreline and relocated the vessels to allow more flexibility in the connected piping. The layout is substantially more flexible than the first, and its loops around the compressor allow axial stops to be introduced. These restrain the effect of external loads while allowing almost unrestrained thermal expansion.

Second piping and compressor arrangement, with piping loops around the compressor.
Second piping and compressor arrangement, with piping loops around the compressor.

The third arrangement kept the same compressor orientation and vessel positions but shortened and partly eliminated those loops. The study expected this to make it slightly less flexible than the second.

API 617 Nozzle Load Factors and ASME B31.3 Stress Results

The second and third arrangements gave much better results than the first, and the preferred arrangement differed by line. Results are expressed as a factor on the basic API 617 allowable, so 1.0 is the standard allowable and 4.0 the study target.

For the 52-inch suction line, the second arrangement gave the best results. In normal operation the nozzle load stayed within the standard API 617 allowable, and the design and most upset cases stayed within the factor-of-four target. Two cases slightly exceeded it: working conditions with ship movement 4, and working conditions with ship movement 2 plus wind. Given the strictness of API 617 at this size, the study considers this result acceptable. The third arrangement gave poorer results for all upset cases on this line.

Nozzle load factor relative to the basic API 617 allowable for the 52-inch low-pressure suction line, second arrangement, across 14 load cases.

On the 36-inch line in the second arrangement, the nozzle load in normal operation was 1.6 times the standard API 617 allowable. All design and upset cases stayed within four times the allowable. The study found the third arrangement less favourable on this line and preferred the second.

In the second arrangement, the 30-inch line stayed within 2.5 times the allowable for all design and upset cases, and the third arrangement gave marginally different results. The 28-inch discharge line stayed within four times the allowable for all design and upset cases in the second arrangement, and the third arrangement gave better results.

High stresses were calculated in the super heater manifold at the downstream end of the discharge line. In the second and third arrangements, the flange connections to the super heater nozzles were modelled as anchors, which removed the super heater’s thermal expansion from the calculation. That model is acceptable for stresses and loads near the compressor but inaccurate for a stress assessment near the super heater, so the study treats the calculated manifold stresses as artificial. With that exception, the results show mild stresses for all arrangements and load cases. The study concludes that all pipe material stresses are acceptable against the ASME B31.3 allowables.

Nozzle Load Limits and Support Design for Motion-Exposed Compressor Piping

The study concludes that a layout and support arrangement keeping nozzle loads within four times the API 617 allowable is feasible, with the second arrangement as the basis. Its only exceedances of the target were the two slight ones on the 52-inch line, which the study considers acceptable.

Third piping and compressor arrangement, with the loops around the compressor shortened and partly removed.
Third piping and compressor arrangement, with the loops around the compressor shortened and partly removed.

Near the compressor, meeting the API 617 nozzle allowables is the main target of the analysis; pipe stress problems are not expected there. In the second arrangement, loops around the compressor allowed axial stops to restrain external loads while leaving thermal expansion almost unrestrained. That arrangement gave the best results for the 52-inch and 36-inch suction lines. No single arrangement was best on every line: the third arrangement was preferred for the 28-inch discharge line, and for the 30-inch line there was no distinct preference between the second and third.

Frequently Asked Questions

Why are API 617 nozzle load allowables difficult to meet on large-bore compressor piping?

API 617 nozzle load limits are more restrictive for larger-bore piping. In this study, assume the bending moment makes the main contribution to the API 617 criterion for the 1200 NB nozzle on a 52-inch suction line. The bending stress in the connected pipe at the allowable limit is then 1.9 MPa, against an allowable stress of 137.9 MPa for the A312 Type 316 pipe material. Because a 1.9 MPa limit is not feasible in practice, the study applied a factor of four to the basic API 617 allowables as its target.

Besides thermal and pressure design loads, the piping in this study had to accommodate storm winds of 85 m/s along the barge centreline. It also had to accommodate barge rocking from wave action, with accelerations of 0.3 g vertical, 0.2 g transverse and 0.1 g longitudinal at the compressor. Wind and wave loads may deflect and bend the lines and generate additional compressor nozzle loads.

The two requirements are in principle in conflict: thermal expansion calls for maximum flexibility, while external loads call for a restraining support arrangement. In the second arrangement of this study, the compressor centreline was reoriented perpendicular to the barge centreline and the vessels were relocated. The piping was routed in loops around the compressor, and those loops allowed axial stops to restrain external loads while leaving thermal expansion almost unrestrained. This arrangement gave the best results for the 52-inch and 36-inch suction lines.

The nozzle load results cover 14 load cases. Two are weight with design pressure and temperature, hot and cold. One is weight with working pressure and temperature (normal operation), and one is working conditions with 85 m/s wind. Eight are working conditions with each of four ship movements, with and without wind. The last two are weight with design or working pressure at ambient temperature.

In the second arrangement, the 52-inch suction line stayed within the standard API 617 allowable in normal operation. Two cases slightly exceeded four times the allowable: working conditions with ship movement 4, and working conditions with ship movement 2 plus wind. The study considers this acceptable. The 36-inch line reached 1.6 times the standard allowable in normal operation and stayed within four times for all design and upset cases. The 30-inch line stayed within 2.5 times, and the 28-inch discharge line within four times, with the third arrangement giving better results for the discharge line.

Near the compressor, pipe stress problems are not expected, and meeting the API 617 nozzle allowables is the main target of the analysis. High stresses were calculated only in the super heater manifold at the downstream end of the discharge line, where the flange connections to the super heater nozzles were modelled as anchors. The study treats those values as artificial. It concludes that all pipe material stresses are acceptable against the ASME B31.3 allowables.