News & Insights from Dynaflow Research Group

surge analysis, GRP, sea water system
Engineering Training

GRP Sea Water System

Introduction The seawater system was classified as a class A system per the Service Limit State (SLS) standards. Constructed from reinforced fiberglass piping, it comprised

Read More »
drilling rig, fiberglass, finite element analysis, fiberglass engineering
Fiberglass Engineering

Pump Lines On A Drilling Rig

Introduction In this case study, the focus was on conducting a stress analysis of the GRE piping system utilized to link the pumps to the

Read More »
Fiberglass Engineering

GRE Seawater Dump Cassion

Introduction In this case study, a finite element stress analysis was conducted on a seawater dump caisson installed on the deck of a floating offshore

Read More »
Pipe stress model of the buried GRE firewater network. The three numbered above-ground steel sections, in red, are modelled as boundary conditions only and are not assessed.

A Buried GRE Firewater Network Brought Within ISO 14692

The Firewater Network The firewater network in this case is built from glass-fibre reinforced epoxy (GRE), grade Wavistrong EST 20, with DN150 pipe running mainly underground. Above ground, steel sections connect to the GRE by flanges, and vertical branches rise to fire hydrants and similar connections. The system was specified

Learn More »
Analysis model of a single radiant coil extended to include the revised outlet piping and its support.
Oil & Gas - Refining

Static Stress Analysis of a Furnace Coil Outlet Piping

Furnace F-501 at a refinery heats crude through radiant coils made of A312 TP316Ti stainless steel. Each coil enters the radiant section at grade level, runs 21 loops parallel to the refractory lined furnace wall, crosses over to the roof section, makes 8 further loops against the roof, and leaves

Learn More »
Mode shapes of the three lowest natural vibration modes, at 1.1 Hz, 1.2 Hz and 1.5 Hz.Mode shapes of the three lowest natural vibration modes, at 1.1 Hz, 1.2 Hz and 1.5 Hz.
Oil & Gas - Refining

Static and Modal Analysis of a Failed Desuperheater Branch Connection

At a refinery, a branch connection designated W31056, the 2″ line that ties in to the high-pressure steam attemperator J-3103 (a desuperheater), failed in service. A similar failure had occurred about twenty years earlier, in 1992. On-site observations report periodic movement of the connecting header, line 6″-S31022, which contains the

Learn More »
Three-dimensional illustration of the analysed cooling water header system.
Oil & Gas - Refining

Flexibility Analysis of a GRE Cooling Water Header Replacement

Two existing steel cooling water headers were to be replaced with Glass Reinforced Epoxy (GRE) piping under two Technical Change Requests. This case study covers the first request, for the main cooling water header “boiler”. The second, covers the “lube” header. A flexibility analysis was required, together with recommendations, to

Learn More »
A hydrogen pipeline to houses illustrating the transformation of the energy sector towards clean, carbon-neutral, safe and independent energy sources to replace natural gas in homes.

Mitigating Vibration-Induced Fatigue in Hydrogen Compressor Branches

Recently, fatigue cracks were discovered in the first-stage discharge line’s small-bore instrumentation branches of a hydrogen compressor. Initial investigations pointed to excessive out-of-plane vibrations as the primary driver of these failures. While the system was originally installed in 1995 with a pulsation study, and further axial supporting was added in

Learn More »
Finite Element Analysis and Verification of Actuator Type F35-340

Finite Element Analysis and Verification of Actuator Type F35-340

Introduction This case study presents the finite element analysis (FEA) and verification process conducted for the pressure-containing parts of the F35-340 actuator, developed by Actuator Technology Company. The primary goal was to demonstrate the structural integrity of the actuator under specified operating conditions and to ensure compliance with the requirements

Learn More »