News & Insights from Dynaflow Research Group

Uncategorized

Pulsations Paper

Benefit of computational simulation of a pulsation dampener compared to an analytical method Accumulators are used to reduce pressure pulsations from reciprocating pumps by adding

Read More »
Axial stress against hoop stress plot for DN100 GRP pipe, with example computed stress points, the 20-year operational envelope and four qualified envelopes.

Stress Review of a Buried GRP Firewater System

Branch Failures in a Buried GRP Firewater Ring The firewater system is made from glass-reinforced plastic (GRP) pipe and is mainly underground. The main is a ring with large-bore branch connections, and smaller-bore branch connections feed the hydrants and monitors above ground. In early operation the system suffered a number

Learn More »
Strut support and the support at node 120 on the vertical piping next to the stripper column. Closing the gaps at node 120 is advised.

Slug Flow Vibration Analysis of a GTL Stripper Feed Line

Slug Flow Operation and Two Elbow Fatigue Failures At a gas-to-liquids facility, the water feed line to an HCN/NH3 stripper (1C-1201) regularly operated in the slug flow regime. Slugs can generate large dynamic loads on the piping, which can eventually result in fatigue failures. Two leakage incidents occurred, each caused

Learn More »

Diagnosing Pulsation in Quadruplex Methanol Pump Piping

Severe Vibration in Vaporiser Feed Pump Piping The suction and discharge piping connected to the quadruplex methanol vaporiser feed pumps was suffering from severe vibration. A pulsation analysis combined with a mechanical response analysis of the as-built piping was performed to establish the root cause. The analyses determined the stress

Learn More »
Sustained stress as a fraction of allowable, shown as a colour plot on the piping model with the modified support arrangement.

Diagnosing Vibration in Reciprocating Pump Piping

At the Utorogu Flow Station in Nigeria, vibration was observed in the suction header, the discharge header and the pump recirculation line. Dynaflow Research Group performed pulsation, mechanical response and static stress analyses to find the root cause, identify any other possible problems and recommend improvements. The station pumps crude

Learn More »
Mode shape of the piping model at 50.1547 Hz (mode 29).

Pulsation and Vibration Analysis of Seal Gas Compressor Piping

Operating Context and Damper Configuration Assumed At a plant in Qatar, a Dresser Roots compressor compresses seal gas in two stages. The client requested a simulation study, both acoustic and mechanical, of the compressor piping between the first-stage discharge and the second-stage suction. The second-stage bypass lines are included. The

Learn More »
Streamlines through the bend and silencer from the CFD model, coloured by velocity magnitude (scale 0 to 60 m/s). A turbulent region is visible in the lower part of the silencer inlet.

CFD Root Cause Analysis of a Recirculation Silencer Failure

A Commissioning Failure That Sent Debris Downstream During commissioning of a natural gas compressor station, pieces of fibreglass fabric, mineral wool and steel wire were found throughout the downstream system. A small amount of mineral wool was also found in the surge valve. Inspection showed that the mineral wool found

Learn More »